Here’s a comprehensive table of Voltas air conditioner error codes, possible causes, and troubleshooting steps:

Error CodeDescriptionPossible CausesTroubleshooting Steps
F1Room Temperature Sensor ErrorFaulty room temperature sensor.Inspect and replace the room temperature sensor if needed.
F2Evaporator Coil Sensor ErrorFaulty evaporator coil temperature sensor.Inspect and replace the evaporator coil temperature sensor if needed.
F3Condenser Coil Sensor ErrorFaulty condenser coil temperature sensor.Inspect and replace the condenser coil temperature sensor if needed.
F4Indoor Fan Motor ErrorMalfunction of the indoor fan motor.Inspect and replace the indoor fan motor if needed.
F5Outdoor Fan Motor ErrorMalfunction of the outdoor fan motor.Inspect and replace the outdoor fan motor if needed.
F6Communication Error (Indoor to Outdoor)Communication failure between indoor and outdoor units.Check for loose or damaged wiring between units.
F7Communication Error (Indoor to Remote)Communication failure between indoor unit and remote control.Check for loose or damaged wiring between indoor unit and remote.
F8Refrigerant Leakage ErrorRefrigerant leakage detected.Inspect for leaks and repair the refrigerant circuit.
F9High Discharge Temperature ErrorHigh discharge temperature of the compressor.Check for issues affecting the compressor and refrigerant circulation.
F10Compressor Sensor ErrorFaulty sensor in the compressor.Inspect and replace the compressor sensor if needed.
F11EEPROM ErrorCommunication error with the memory chip.Consult a professional technician for EEPROM chip replacement.
F12Current Sensor ErrorFaulty current sensor.Inspect and replace the current sensor if needed.
F13Zero-Cross Signal ErrorError in the zero-cross signal.Check for wiring issues and replace the control board if necessary.
F14Overload ErrorOverload in the compressor.Check for electrical issues, and consult a professional technician.
F15Voltage ErrorVoltage outside the normal range.Check the power supply and voltage stability.
F16IGBT High-Temperature ErrorExcessive temperature in the IGBT module.Inspect for overheating issues and improve ventilation.
F17Pressure Sensor ErrorMalfunction of the pressure sensor.Inspect and replace the pressure sensor if needed.
F18EEPROM Error (Remote)Communication error with the memory chip in the remote control.Replace the remote control or consult a professional technician.